产品介绍
|
5077206MS Single Tuning SolutionKit includes one tube of MS Single Tuning Solution (25mL) and one MS Wash Solvent ( 25mL). Calibration kit for SCIEX Triple Quad 7500 system - QTRAP Ready.
4406127 MS Chemical kit 1, low-high conc. PPGs Standards chemical kit with low/high concentrations of polypropylene glycol polymers (PPGs).This kit includes all solutions necessary for installation and calibration for all SCIEX Triple Quads, excluding the API 2000 and API 3000 series.
4412399 MS Chemical kit 2, higher conc. PPGs Standards chemical kit with high concentrations PPGs.This kit includes all solutions necessary for installation and calibration for all API 2000 and API 3000 series instruments.
4465788 SelexION Calibration solution Installation and Calibration Solution for SelexION differential mobility spectrometry (DMS)
5077206MS Single Tuning Solution Kit includes one tube of MS Single Tuning Solution (25mL) and one MS Wash Solvent ( 25mL). Calibration kit for SCIEX Triple Quad 7500 system - QTRAP Ready.
4406127 MS Chemical kit 1, low-high conc. PPGs Standards chemical kit with low/high concentrations of polypropylene glycol polymers (PPGs).This kit includes all solutions necessary for installation and calibration for all SCIEX Triple Quads, excluding the API 2000 and API 3000 series.
4412399 MS Chemical kit 2, higher conc. PPGs Standards chemical kit with high concentrations PPGs.
This kit includes all solutions necessary for installation and calibration for all API 2000 and API 3000 series instruments.
4465788 SelexION Calibration solution Installation and Calibration Solution for SelexION differential mobility spectrometry (DMS)
MS calibration kits for TripleTOF instruments
4465920 Tuning Solution Kit used for resolution and sensitivity of the TOF high mass and MS/MS high mass in positive mode. Kit contains a bottle of tuning solution formulated with CSL and a peptide. This is identical to the tuning solution found in installation kit for SCIEX TripleTOF system (part #4456736).
4460131 APCI Positive Calibration Solution 5600 This calibration solution for the TripleTOF 5600 system is intended for positive ion mode with the DuoSpray source. Calibration solution is introduced using the atmospheric-pressure chemical ionization (APCI) probe; sample analysis is with electrospray ionization (ESI) probe.
4460134 APCI Negative Calibration Solution 5600 This calibration solution for the TripleTOF 5600 system is intended for negative ion mode with the DuoSpray source. Calibration solution is introduced using the APCI probe; sample analysis is with ESI probe.
4460136 APCI Positive Calibration Solution 5600 5pk This calibration solution (five pack) for the TripleTOF 5600 system is intended for use in positive ion mode with the DuoSpray source. Calibration solution is introduced using the APCI probe; sample analysis is with the ESI probe.
4460138 APCI Negative Calibration Solution 5600 – 5 pack The calibration solution (five pack) for the TripleTOF 5600 system is intended for use in negative ion mode with the DuoSpray source. The calibration solution is introduced using the APCI probe; sample analysis is with the ESI probe.
4463272 ESI Positive Calibration Solution 5600 The calibration solution for the TripleTOF 5600 system is intended for use in positive ion mode with the DuoSpray source. The calibration solution is introduced using the ESI probe; sample analysis is with the APCI probe.
4463274 ESI Positive Calibration Solution 5600 – 5 pack The calibration solution (five pack) for the TripleTOF 5600 system is intended for use in positive ion mode with the DuoSpray source. The calibration solution is introduced using the ESI probe; sample analysis is with the APCI probe.
4463276 ESI Negative Calibration Solution 5600 – 5 pack The calibration solution (five pack) for the TripleTOF 5600 system is intended for use in negative ion mode with the DuoSpray source. The calibration solution is introduced using the ESI probe; sample analysis is with the APCI probe.
4463277 ESI Negative Calibration Solution 5600 The calibration solution for the TripleTOF 5600 system is intended for use in negative ion mode with the DuoSpray source. The calibration solution is introduced using the ESI probe; sample analysis is with the APCI probe.
4456736 Installation kit for SCIEX TripleTOF 5600 system Kit used for installation of the 5600 family of instruments
|